Connect the DSP to telnet through USB(169.254.99.202) or through LAN(user defined IP Address) at port 23.Use username:clearone,Password:converge.Enter "FACTORYDEFAULT" to factory reset the DSP.
The Plink device detection can be checked by sending the command "PLN *" using telnet. The response would be PLN,(Device serial no). If you don't get that response then the Plink device connectivity is not detected.
The Dante ports IP Address is auto assigned and we cannot assign an ip address. The IP address can be viewed in the Dante control software or using telnet with the command -BOX BOXname DANTE IP_ADDRESS1
1) Send the command "VOIPUPDATE *" through telnet and the response should be "REG Succeed" to confirm a successful registration. If you don't get that reply, the registration wass unsuccessful. 2) When connected through ClearOne Dialer with ...